U-Value Analysis Of Coil in Box Heat Exchangers Using Log Mean Temperature Difference (LMTD) Method
DOI:
https://doi.org/10.24127/trb.v13i2.3407Keywords:
heat exchangers, evaporator, refrigeration, vapor compression, coil in boxAbstract
Heat exchangers take an important role in the vapor compression refrigeration system as either condenser or evaporator. In this study, the development of coil in box heat exchangers was conducted and analyzed as an evaporator. The device consisted of an insulated box with dimensions of 28 cm x 18 cm x 20 cm and the copper pipe with 0.006 m diameter and 3.65 m length. The heat was exchanged between the refrigerant R134a inside the pipe and the air outside the copper pipe. The temperatures at the inlets and outlets were measured by K-type thermocouples. Multiple experiments with the different air velocities were conducted. The log mean temperature difference (LMTD) method was used to analyze the overall heat transfer coefficient (U-Value) of the heat exchanger. The results show that the average U-Value was 76.9 W/(m2K).
Downloads
Published
Issue
Section
License
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge.
All articles published Open Access will be immediately and permanently free for everyone to read and download. We are continuously working with our author communities to select the best choice of license options, currently being defined for this journal as follows:

TURBO by JURUSAN TEKNIK MESIN is licensed under a Creative Commons Attribution 4.0 International License.